8.4.6 Initial effect – This function allows a user to create and assign a custom “Home

Position.” Adjusting the Pan and Tilt values then locking those values into the fixture’s

internal memory creates the new “Home” position. Restoring the fixture’s factory values

can erase this setting.

8.4.7 Restore Default – This function is used to restore the factory settings of the

device. All settings will be set back to the default values (shaded). Any edited scenes will

be lost.

8.5 Reset Functions: The reset function returns a motor to the “Home” position. There are

several reset functions available on this fixture. The list below details the functionality of

each available selection.

Reset All: This function will reset all internal motors to the home position.

Reset Pan and Tilt: This function will only reset the pan and tilt motors to the home

position.

8.6 Effect Adjust:

8.6.1 Test Channel – This menu function allows the user to select each individual

fixture channel and test it’s function independently from the control board.

8.6.2 Manual Control –This function will center the pan and tilt motors and bring all

LEDs to 100%, then allowing manual control of all functions. The pan and tilt

function will still operate if the fixture needs to be positioned to a flat clear surface.

8.6.3 Calibrate values – This function should only be performed by a technician

familiar with the operations of fixtures of this type. This function allows a user to

make small adjustments to the motor alignment to compensate for wear or a

sensor slightly out of place. Because improper use of this function can result in

undesired operation this function has been password protected. The password is

050 and must be entered each time the calibration menu function is entered.

Because calibration is an extremely delicate procedure instruction on performing

this action are left out of this manual. For a first time calibrator, please contact our

Advertising