Vacuuming the scanner – Kodak i2420 User Manual

Page 27

Advertising
background image

A-61677 November 2016

21

4. Inspect the feed module.

If the feed module tires show signs of wear or damage, replace the
tires or the feed module. See the “Replacement procedures” for
more information.

5. Use a vacuum or cleaning pad to remove dust and debris from the

feed module area.

6. Reinstall the feed module by aligning the pins and pushing it toward

the left to fit it into position. Be sure the gears are aligned and it
snaps into place. Roll the feed module back into place.

7. Reinstall the feed module cover by aligning the tabs with the slots

and pushing it back into position until it snaps into place.

Vacuuming the scanner

Before cleaning the imaging area, it is suggested that you vacuum the
inside of the scanner to remove any dust and debris.

Advertising