1 servomotor installation environment – Yaskawa AC Servo Drives DC Power Input Sigma-5 Series User Manual

Page 19

Advertising
background image

2 Installation

2.1.1 Servomotor Installation Environment

2-2

2.1

Installation Environment and Applicable Standards

The installation environment and the applicable standards for servomotors and
SERVOPACKs are described in this section.

2.1.1

Servomotor Installation Environment

„

Ambient temperature: 0 to 40

°

C

„

Ambient humidity: 80% RH or less (with no condensation)

„

Altitude: 1, 000 m or less

„

Vibration resistance

„

Shock resistance: 490 m/s

2

at servomotor flange

Impact occurrences: 2

„

Installation site: An environment that satisfies the following conditions

• Indoors and free of corrosive or explosive gases

• Well-ventilated and free of dust and moisture

• Facilitates inspection and cleaning

• Free of high magnetic field

The servomotor will withstand the following

vibration acceleration in three directions: vertical,

side to side, and front to back.

Servomotor Model

Vibration Acceleration

at Flange

SGMMV

49 m/s

2

Horizontal

Impact applied to the

servomotor

Vertical

Front to

back

Side to side

Advertising