3.3 Main Circuit Wiring

3-9

3

Wiring and Connection

3.3.3

Typical Main Circuit Wiring Examples

The following wiring examples show the DC Power Input

Σ

-V Series SGDV SER-

VOPACK (Analog voltage reference model).

„

SGDV-

†††

ES1A (

†††

= 1R7, 2R9)

• Use a molded-case circuit breaker (1QF) or fuse to protect the

servo system.
Always use a molded-case circuit breaker (1QF) or fuse to pro-
tect the servo system from accidents involving different power
system voltages or other accidents.

• Install a ground fault detector.

The SERVOPACK does not have a built-in protective circuit for
grounding.
To configure a safer system, install a ground fault detector
against overloads and short-circuiting, or install a ground fault
detector combined with a molded-case circuit breaker.

• Do not frequently turn power ON and OFF.

• Frequently turning power ON and OFF causes elements

inside the SERVOPACK to deteriorate. Do not use the servo
drive with an application that requires frequently turning power
ON and OFF.

• After the actual operation starts, the allowable interval for turn-

ing power ON and OFF is one hour or longer.

L1

ENC

SGDV SERVOPACK

U

V

W

M

0 V

1Ry

8

11

1D

1KM

Insulated AC/DC

converter for main

circuit power supply

L2

CN1

1QF

R

T

+24 V

(For servo

alarm display)

1Ry

1PL

1KM

1SA

Servo

power

supply

ON

Servo

power

supply

OFF

1KM

1Ry

1QF
1FLT
1KM

: Molded-case circuit breaker
: Noise filter
: Magnetic contactor
(for main power supply)

1Ry
1PL
1SA
1D

: Relay
: Indicator lamp
: Surge absorber
: Flywheel diode

C1
C2

FG

ALM

COM_SG

1FLT

CN4

CN3

Insulated AC/DC

converter for control

circuit power supply