4.2 Inspection and Checking before Trial Operation

4-3

4

T

rial Operation (Checking Servomotor Operation)

4.2

Inspection and Checking before Trial Operation

To ensure safe and correct trial operation, inspect and check the following items
before starting trial operation.

„

Servomotors

Inspect and check the following items, and take appropriate measures before per-
forming trial operation if any problem exists.

• Are all wiring and connections correct?
• Are all nuts and bolts securely tightened?
• If the servomotor has a brake, is the brake released beforehand? To release the

brake, apply the specified voltage (24 VDC). The following diagram shows an
example of the circuit wiring needed to release the holding brake before a trial
operation.

An Example of Wiring for Circuits

A 24-VDC power supply for the brake is not included.

Servomotor with

holding brake

SERVOPACK

Power

supply

M

BK

ENC

U

V

W

CN2

L1
L2

C1
C2
FG

CN3

CN4

Brake power supply*

Insulated AC/DC

converter for main

circuit power supply

Insulated AC/DC

converter for control

circuit power supply

Advertising