3 jog operation using a digital operator – Yaskawa AC Servo Drives DC Power Input Sigma-5 Series User Manual

Page 45

Advertising
background image

4 Trial Operation (Checking Servomotor Operation)

4-6

4.3

JOG Operation Using a Digital Operator

This section describes the procedure for executing a JOG operation using a digital
operator. The following illustration shows how to connect the digital operator.

The digital operator can be connected or removed while the SERVOPACK power is
ON.

• The digital operator is available for both SERVOPACKs with analog

voltage reference and SERVOPACKs with pulse train reference.

• The tuning-less function is by default set enabled. When the tun-

ing-less function is enabled, the gain may be so increased to
cause vibration during no-load operation. If vibration occurs, dis-
able the tuning-less function by setting the parameter Pn170.0 to
0.

SGDV

SERVOPACK

Σ

-V series

JUSP-OP05A-1-E

Digital Operator

Digital operator junction connector
Model: JZSP-CF1S00-A3-E

Insert securely into
SERVOPACK CN5 connector.

Step

Display after operation

Keys

Operation

1

Turn ON the power to the SERVO-

PACK. A message saying that the file

list is being loaded will appear and then

the parameter/monitor mode will

appear.