Appendix – Elmo HV-8000SX User Manual

Page 45

Advertising
background image

- 44 -

Item

Outline

IP Address

The IP address of the Presenter.
Specifies the value allocated by the administrator of the network in use.
Factory set to 192.168.0.100.

root password

The password for setting up the network and using telnet. Not factory set.
Should preferably be set for the security purpose.

user password

The password for setting up the FTP client to enable the use of the image transfer button
[IMAGE TRANSFER] and for using the FTP server function. Not factory set.

Subnet mask

The mask value for separating the network address from the host address.
Used in combination with the IP address to specify the network to which this Presenter
belongs.Specifies the value allocated by the administrator of the network in use.
Factory set to 255.255.255.0.

Default
Gateway

Specifies the IP address of the router when this Presenter is used on the network equipped with
a router. For the IP address of the router, ask the administrator of the network to in use. Factory
set to 0.0.0.0. Set to 0.0.0.0. when using the Presenter on the network equipped with no router.

Item

Outline

IMAGE TRANSFER

Specifies Enable/Disable of the image transfer button [IMAGE TRANSFER]. Factory set to Disable.

The IP address / the
image receiving server

Specifies the IP address of the destination host to save.
Factory set to 0.0.0.0.

The port number / the
image receiving server

Specifies the port number used by the FTP server in operation at the destination host to save.
Normally, no need to be changed. Factory set to 21.

The account / the
image receiving server

Specifies the account name used for connection to the destination host to save.
Factory set to anonymous.

The password / the
image receiving server

Specifies the password of the above account.
Not factory set.

Passive mode

Specifies which mode is used for file transfer, the passive mode or active mode.
When the port is limited by firewall, etc., use the passive mode. For whether the passive mode
should be used or not, ask the administrator of the network in use. Factory set to no use.

Destination
directory to save

Specifies the destination directory to save the image file. Specifies the write-enabled directory
of the assigned account. Not factory set. (The root directory has been specified.)

Image size

Specifies the size of image to be saved from among SXGA, VGA and QVGA. The image sizes
are 1280X1024 for SXGA, 640X512 for VGA, and 320X256 for QVGA.
Factory set to SXGA.

File name of
image

Specifies the name of the file to be saved. Automatically adds the extension [.jpg] to the file
name. Since any file under the same name in the saving destination is overwritten, specify a
different file name from the existing file names. Factory set to [img].

Add sequential
number to file
name

Specifies whether Yes/No to the addition of sequential number to the file name. When [Yes] is
specified, the image is saved under the file name specified for the image with the sequential
number added (e.g., img000000.jpg, img000001.jpg) each time the file is saved. When the
power supply to the Presenter is turned ON or the FTP client settings are changed, the
sequential number to be added to the file name is reset to the number specified for the star
number of sequence. Factory set to Yes.

Start number of
sequence

Specifies the start number of sequence when the sequential number is add to the file name.
Factory set to [0].

End number of
sequence

Specifies the end number of sequence when the sequential number is added to the file name.
When the sequential number reaches the end number, the sequential number returns to the start
number of sequence. Then, if there is a file already saved with the start number of sequence,
that file will overwritten when the new file is saved. Therefore, the end number of sequence
should preferably be larger. Factory set to 999.

Appendix

Setting items of the network

Setting items of the FTP client

Advertising