Spare drives, Definition, Options – Promise Technology 2-Year Extended Warranty for VessR2000 RAID Head User Manual

Page 607: Pare, Rives, Efinition, Ptions

Advertising
background image

580

Vess R2000 Series Product Manual

Promise Technologies

s

pare

d

riVes

Spare drive technology includes:

“Definition” (below)

“Options” (below)

“Requirements” on page 581

“Transition” on page 581

D

efInItIon

A spare drive is a physical drive that you designate to automatically replace the failed physical drive in a disk

array. See “Creating a Spare Drive Manually” on page 214.

The general recommendation is to:

• Provide at least one spare drive for every 16 physical drives in the RAID system

• Configure the spares as global revertible spare drives

o

PtIonS

There are several options you can specify for a spare drive:

• System Options

• Revertible – Returns to its spare drive assignment after you replace the failed physical drive in the disk

array and run the Transition function.

• Media Patrol – By default, Media Patrol runs on spare drives unless you disable it.

• Spare Type

• Global – Can be used by any disk array

• Dedicated – Can be used only by the assigned disk array

• Media Type (type of physical drive)

• Hard Disk Drive (HDD)

• Solid State Drive (SSD)

Advertising