Promise Technology 2-Year Extended Warranty for VessR2000 RAID Head User Manual

Page 611

Advertising
background image

584

Vess R2000 Series Product Manual

Promise Technologies

If a physical drive fails in a disk array and there is a spare drive of adequate capacity available, the controller

automatically rebuilds the array using the spare drive. In this example, physical drive 3 failed and the array is

rebuilt using physical drive 6, the revertible spare drive.

When the rebuild is complete, the spare drive has replaced the failed drive. In this example, failed drive 3 was

replaced by spare drive 6. The disk array now consists of physical drives 1, 2, 4, and 6.

There is no spare drive at this moment. Even if physical drive 5 is of adequate capacity, it has not been

designated as a spare, therefore the controller cannot use it as a spare.

1

2

3

4

5

6

Array

Drives

Advertising