EMI S2HB User Manual

Page 3

Advertising
background image

www.enviromaster.com

3

multi-zone Heat Pump Condensing units

EMI AMErIcA SErIES MultI-zonE HEAt PuMP condEnSIng unItS

• Compressor and Fan Motor Contactor

• Capacitor

• Low Voltage Connections

• Large Capacity Suction Accumulator (9,

12, & 18 Only)

• High Pressure Control (18 & 24 Only)

• Solid Core Filter Drier

• Thermostatically controlled crankcase

heater

(9&12 Only)

• Common suction pressure access point

• Hard Start Capacitor

iTemS For ConSideraTion

• Locate the unit as close to the indoor sec-

tion as possible. Maximum length allowed

is 100 equivalent feet.

• Avoid high traffic areas and prevailing

wind locations.

• Surface must be level.

• Mount unit above typical snow levels.

Ensure free air flow through the unit. Air

must not recirculate from discharge to in-

take. Air is drawn through the coil with side

or top and discharged through the fan grille.
A minimum 48” clearance is necessary
for the condenser discharge. Intake
(coil side) clearance is 12” minimum.

Consider how power will be run to the unit

from the power source. Refrigerant piping

must be a direct line to the indoor unit.

Heat pump units produce condensate in the

heat pump mode. Water will drain from the

unit at the base. Place the unit so as not to

create a hazard for pedestrians.

SYSTem oPTionS

• Sea Coast Style Coated Coils /

Copper-Copper coils

• Wind Baffles - Louvers

inSTaller SuPPlied iTemS

• Power wiring

• Low Volt wiring - 18 AWG minimum

• Secure mounting pad or foundation

• Refrigerant piping

• Disconnect switch

SiTe PreParaTion

Place the unit on a flat concrete surface or

pad if on the ground. Roof mounting should

use a build up platform. Piping is through

the wall or roof directly to the unit. In areas

of heavy snowfall, condensers should be

set above the level of maximum anticipated

snowfall (12” is usually adequate).

EMI offers the finest multi-zone heat pump

outdoor units in the ductless split market, the

S & T series (S2HB, T2HB, T3HB & T4HB)

Condensing Units. The S & T series (S2HB,

T2HB, T3HB & T4HB) allows the installation of

two or more circuits from a single outside location

when space or aesthetic requirements limit the

use of the number of cabinets outdoors. Each

zone is independent so no mixing of refrigerant
occurs.

When specifying heat pump(s), it is

recommended that the matching indoor unit(s)

be equipped with electric heat. All 9,000, and

12,000 Btuh circuit units are equipped with the

Duratec Performance Package which includes

a large capacity suction accumulator with

surge baffles and enhanced oil management,

and a factory installed solid core filter drier. All
18,000 and 24,000 Btuh circuit units include

a solid core filter drier and high pressure limit
switch. The 18,000 Btuh circuits also include a

large capacity suction accumulator with surge

baffles and enhanced oil management.

noTe: The crankcase heater is installed
with 9,000 and 12,000 Btuh heat pumps.

ConTrolS and ComPonenTS

(FACTORY INSTALLED OR SUPPLIED)

deSCriPTion

Thermostatically controlled crankcase
heater

– This feature energizes the crank-

case heater only when needed, removes

the heater from the electrical circuit at

conditions where it’s not required, saving

unnecessary Watts, and increasing overall

system efficiency.

Advertising