Initial installation, Clearances to combustibles, B vent model – Enviro FOCUS EG31-118 User Manual

Page 12: Automatic flue gas spill switch

Advertising
background image

12

Initial Installation

Check draft

with a match

or smoke in

a 1⁄4" (6 mm)

tube located

here.

Warning: Failure to position the parts in accordance with this manual, or failure to use only parts

specifically approved with this appliance may result in property damage or personal injury.

C

LEARANCES

TO

C

OMBUSTIBLES

:

Mantle pillar to glass door

9” (22.8 cm)

From floor to 8” wide mantle

38” (96.5 cm)

Minimum non-combustible surface in front of unit 11” (27.9 cm)

Warning: Clearances must be sufficient to allow access for operation, maintenance and service. Stove

must sit on a non-combustible surface.
Depth of unit into fireplace 16” (41 cm)

Depth of unit out of fireplace 3’’ (7.6 cm)
Minimum fireplace size:

Width 34” (86.36 cm)

Height 21” (53.3 cm)

Depth 18” (45.7 cm)

B V

ENT

M

ODEL

:

WARNING: This appliance has been designed to operate by drawing combustion air and dilution air

from the room. It is also designed to draw room air for proper heat circulation from the sides of the

unit. Blocking or modifying the louvers in any way can create hazardous situations, either through poor

venting or by overheating. It is important that this unit has sufficient air circulation for proper venting

and combustion. Provisions must be made for the supply of adequate combustion and ventilation air.

These openings must not be blocked. The appliance must not be connected to a chimney flue servicing

a separate solid fuel burning appliance.

A

UTOMATIC

F

LUE

G

AS

S

PILL

S

WITCH

:

NOTE: This heater must be properly connected to a venting system. This heater is equipped with a vent

safety shutoff system designed to protect against improper venting of combustion products. This safety

switch is located on the rear of the appliance close to the draft hood relief opening. If the switch trips

more than once, the venting should be inspected by a qualified service technician for possible blockage

or severe down draft conditions.
BV Only: The draft hood must be in the same pressure zone as the air inlet. To inspect draft from

WARNING: Operation of this heater when not connected to a properly installed and maintained

venting system can result in carbon monoxide (CO) poisoning and possible death.

the front of the unit, locate the 1⁄4” tube between

the louvers (see Figure 13) and check for a draft

using smoke. A vacuum or suction into the tube will

indicate proper drafting.
This model can be vented with 4” aluminum or

stainless steel flex vent and/or certified Type B Gas

Vent. The flue collar of the appliance will fit inside

of a standard 4” vent and may be fastened directly

to the vent, check periodically that the vent is

unrestricted and an adequate draft is present when

the unit is in operation.

Figure 13: Draft Check.