Move the rod located behind the

piezo ignitor to increase or decrease

primary air at the venturi tube.

There is only one (1) venturi and one (1) air shutter

to be adjusted.
When installing the burner top, ensure that

the venturi tube is engaged to the air shutter

adjustment rod.
Use this small venturi adjustment rod to achieve a

proper and efficient flame, shown in Figure 5.
Adjust rod until the flame pattern is similar to

Figure 33.

Table 1: Venturi Setting.

Natural Gas

Propane

Venturi Setting Rear

1

/

16

” min.

3

/

16

” min.

Figure 5: Venturi Air Setting Rod

7

Operating Instructions

A

DJUSTING

V

ENTURI

A

IR

S

ETTINGS

:

B

LOWER

SPEED

:

The blower will come on only when the fireplace is up to temperature (approximately 20 minutes). The

speed of the fan can be changed by turning the fan control knob. To turn the blower off, turn the knob

COUNTER CLOCKWISE until it “clicks” off.
It is advisable not to operate the blower below

1

/

3

speed as it puts a strain on the windings of the blower

and running the blower at lower speeds could also cause premature fan failure.

N

ORMAL

S

OUNDS

D

URING

O

PERATION

:

Table 2: Normal Sounds.

Component

Sound & Reason

Focus & Fascia

Creaking when heating up or cooling down.

Burner

Light pop or poof when turned off; this is more common with LP units.

Temperature Sensor

Clinking when it senses to turn the blower on or off.

Pilot Flame

Quiet whisper while the pilot flame in on.

Blower / Fan

Air movement that increase and decreases with the speed of the blower. The

blower is pushing the heat from the fireplace into the room.

Gas Control Valve

Dull click when turning on or off, this is the valve opening and closing.