Direct vent model, Direct vent restrictor ring, Preparing your focus for installation – Enviro FOCUS EG31-118 User Manual

Page 13: Initial installation

Advertising
background image

P

REPARING

Y

OUR

F

OCUS

F

OR

I

NSTALLATION

:

1. Remove the appliance and surround panels from the packaging; check to make sure there is no

damage. Carefully check the glass door. Do not use the unit if it is damaged. In the event damage is

found, please report it to both the courier and your dealer as soon as possible.

2. Carefully clean the fireplace and flue before installing the stove. Failure to do so may result in fumes

or dirt being blown into the room and may cause a fire leading to death or serious injury.

3. Remove the glass door; see M

AINTENANCE

A

ND

S

ERVICE

- G

LASS

D

OOR

R

EMOVAL

.

4. Remove log and ember set and all wrapping material from inside the stove. Remove wrapping material

from log and embers and check for any damage. If damage is observed, do not use unit and contact

your local dealer.

5. Remove the vent collar plate from the top of the stove by unscrewing the two (2) T-20 Torx screws

located on the center top of the stove. Slide collar plate backwards. Properly secure the vent collar

plate to the flexible vent pipe liner(s) previously installed in the chimney. Be careful not to over-stretch

the liner(s).

6. Install the leveling legs. Thread the two (2) 5” (13 cm) bolts and locknut up into the captive nuts at

each end of the leveling leg bracket (refer to Figure 15).

Initial Installation

QUALIFIED INSTALLERS ONLY

D

IRECT

V

ENT

M

ODEL

:

WARNING: This appliance has been designed to draw room air for proper heat circulation

from the sides of the unit. Blocking or modifying the louvers in any way can create hazardous

situations.
This model is vented with TWO (2) 3” aluminum or stainless steel flex vent leading into a co-linear to co-

axial vent adaptor and using a Simpson Dura Vent vertical termination cap. The flue collars of this model

will fit inside of standard 3” vent and may be fastened directly to the vent. The Exhaust vent is in the

center of the flue connector. The Air Intake is on the left side of the vent collar plate (this outlet is not in

the center it is off to one side of the vent collar plate.)
Check periodically that the vents are unrestricted. Also ensure that all direct vent pipes have been

properly sealed and installed after routine inspection or cleaning. The air intake and exhaust pipes must
be installed in the correct locations on the removable draft hood connector.

D

IRECT

V

ENT

R

ESTRICTOR

R

ING

:

Figure 14: Direct vent restrictor ring installation.

Vent Restrictor Ring

DIRECT VENT ONLY: The maximum vertical vent

height for a direct vent installation is 25 feet (7.62 m).

Use the vent restrictor ring for installations above 15

feet (4.57 m). See Figure 14 for installation of restrictor

ring.

13