Electrical requirements, Initial installation, Qualified installers only e – Enviro FOCUS EG31-118 User Manual

Page 18

Advertising
background image

18

FAN

TP TP/TH

TH

Fan

Control

120

o

F (49

o

C)

Temperature Sensor

Blue

Orange

Black

White

Green

White

Black

Orange

White
Green/Yellow

Power Cord

120V AC

300

o

F (149

o

C) Manual

Reset Spill Switch

For DV Only

Grey

Grey

Blue

Blue

Blue

Grey
Purple

Place Thermostat

Wires Here.

On/Off/Thermostat

Switch

The Focus will operate without

electrical power. This model has

a Millivolt gas control which uses

the pilot flame to generate enough

electricity to operate the main burners.

This appliance when equipped with a

blower, must be electrically connected

and grounded in accordance with

local codes or in the absence of local

codes, with the current CSA C22.1

CANADIAN ELECTRICAL CODE Part 1,

SAFETY STANDARDS FOR ELECTRICAL

INSTALLATIONS, OR THE NATIONAL

ELECTRICAL CODE ANSI / NFPA 70 in

the U.S.
WARNING: Electrical grounding

instructions. This appliance is equipped

with a three-prong (grounding) plug for

your protection against shock hazard,

and should be plugged directly into a

properly grounded three-prong outlet.

DO NOT cut or remove the grounding

prong from this plug.

CAUTION: Label all wires prior

to disconnection when servicing

controls. Wiring errors can cause

improper and dangerous operation.

Verify proper operation after

servicing.

Table 3. Recommended Thermostat

Wire Size.

Wire Size

Max. Length

14 gauge

100 ft (30.48 m)

16 gauge

60 ft (18.29 m)

18 gauge

40 ft (12.00 m)

20 gauge

25 ft (7.62 m)

22 gauge

18 ft (5.49 m)

COOL / HEAT
PROGRAM

DOWN

UP

70 ° F

70 ° F

ON

OF

F

Optional

Remote

Control

Purple

Grey

Optional

Wall Switch

Optional

Thermostat

Pilot

Adjustment

Screw

ON/OFF/REMOTE

Thermostat Switch

Blue

Thermopile

Thermocouple

Manifold

Pressure

Tap

Inlet

Pressure

Tap

Gas

Control

Valve

BV Only

300

o

F (149

o

C)

Temperature

Sensor

(DV has only

connectors)

Blue

Figure 26: Wiring of a Thermostat.

Figure 25: Focus Wiring Diagram.

Initial Installation

QUALIFIED INSTALLERS ONLY

E

LECTRICAL

R

EQUIREMENTS

:

Advertising