Temp, Fans – Elation Professional Power Wash 250B User Manual

Page 22

Advertising
background image

Power Wash 250™

©Elation Professionals® Los Angeles, Ca. - wwww.ElationLighting.com - Page 22

Press Enter to confirm or Mode to cancel and return to the menu.

D ON

Display On/Off (If you've chosen

off

, the display will go out

within 15 seconds after the last input. The next key touch will
reactivate the display).

REV

Turn around the display

3.10.6 Fixture Temperature

(TEMP)

TEMP

This function allows you to read out the actual fixture operating
temperature. Press the Enter button to confirm or the Mode to button to
cancel and return to the main menu. Normal operating temperature should
range between 85˚C and 95˚C. Operating temperatures between 96˚C and
104˚C are considered critical. Temperatures above 105°C will send the
fixture into protect mode and automatically switch the lamp off, the lamp will
remain off until internal temperature drops below 95˚C.

3.10.7 Fan Control

(FANS)

FANS

By using this function you can choose between 4 types of fan speed
operations. Use the Up and Down buttons to select the desired function
and press Enter to confirm or Mode to cancel and return to the menu. The
chart below will detail the different fan settings:

HIGH

The cooling fan works continuously at max. speed.

REG

This is the default fan setting. In this setting an internal thermal
sensor constantly monitors the internal operating temperature
and regulates the fan speed to coincide with the internal
temperature.

LOOF

This function is designed for environments that require low
ambient noise. In this setting the fan will operate at the lowest
speed. When the maximum internal intolerable operating
temperature is reached the lamp will automatically shut off.

LOHI

In this setting the fan will operate at the lowest speed. When the
maximum internal intolerable operating temperature is reached
the fan will automatically switch from low to high speed.

Advertising