Initial installation – Enviro C-11089 User Manual

Page 26

Advertising
background image

G

AS

L

INE

C

ONNECTION

:

an access hole of 1.5 in (37.5mm) or less may be drilled through the lower sides or bottom of the firebox

in a proper workmanship like manner. This access hole must be plugged with non-combustible insulation

after the gas supply line has been installed.”
• A shut-off valve is not supplied with this unit but one should be installed.
• The appliance and its shut-off valves must be disconnected from the gas supply piping system during

any pressure testing where the pressure exceeds 1⁄2 psig (3.45 KPa) or the valve will be damaged.
• The unit must be isolated from the gas supply piping system by closing its individual manual shut off

valve during any pressure testing of the gas supply piping system at pressures equal to or less than

1⁄2 psig (3.45 KPa).

Warning: Only persons licensed to work with gas piping may

make the necessary gas connections to this appliance.

Gas Line Connection:
• A 3⁄8” NPT male pipe will have to be turned into the 3⁄8” NPT

female elbow at the lower right side rear of this fireplace (see

Figure 53). Consult the local authorities for local codes or use the

CAN/CGA B149 (1 or 2) installation code in Canada. In the US, gas

installations follow either local codes or the current edition of the

National Fuel Gas Code ANSI Z223.1.
• The efficiency of this unit is a product thermal efficiency rating

determined under continuous operating conditions and was

determined independently of any installed system.
• If the factory-built fireplace has no gas access hole(s) provided,

Figure 52. Remove/Install Control Panel.

Figure 51: Grounding Power Cord.

11. Make note of the order the connectors are in on the

three (3) position switch and remove them. Slide the

switch through the front of the hole that was just

8. Pull the control panel straight out (see Figure 52). There are two (2) tabs on the bottom of the control

panel that fit in two (2) slots in the Sonnet cabinet bottom.

9. Slide the temperature sensor into the holding tabs below the left end of the burner behind the control

panel.

10. Using a utility knife cut out the rectangle on the control panel between the two (2) fan symbols.

Initial Installation

QUALIFIED INSTALLERS ONLY

cut out and

reattach the

connectors to

the switch.

12. Re-install the

control panel.

Figure 53: 3⁄8” NPT female elbow.

26