3-13. PREVENTIVE

Inspect Counter-weight Cables-Annually

MAINTENANCE

Continued

Henny Penny 8 head fryers use two cables in the counter-weight

mechanism that helps in the raising and lowering of the lid. Cables

should be visually inspected yearly, either as part of a planned

maintenance program or during a routine service call. Cables more

than 10 years old should be replaced regardless of inspection results.

1.

Using a 3/8” socket, remove the 6 keps nuts around

exterior of rear cover, shown in Figure 1.

2. Lift up on the rear cover and pull out at the bottom to clear

threaded studs. Figure 2. (Removing top shroud makes it easier

to remove the rear cover, but is not necessary.)

Figure 1

Figure 2

View of the counter-weights
with cover removed

If lid becomes difficult to operate, stop using the fryer and

call for service. Cables need replaced.