3-14. PROGRAMMING
(continued)

13.

After the end-of-cycle point is set, press and release the
FUNCTION button. “HEAD” flashes on the left side of the
display and a number shows on the right side of the display.
The number on the right, is the number of head of chicken to
be cooked at one time, when that product button is pressed.
The number can be changed by pressing the appropriate
product button. The control can then accumulate the head
count (usage) of that product, based on counting the number
of Cook Cycles.

Another product can be programmed while in the program
mode by following these procedures:

Press and hold the SCAN button at any time while in the
Program Mode and the display will scroll “SELECT PROD-
UCT”. Then press any of the product buttons, (1-0), and
now that product can be programmed.

14.

To program second interval, press and release the
SCAN button while in the Time Mode of the first mode.
“INT2” and “TIME” will flash on the left side of the display.
Then follow the steps above, starting with step 4.

3-15. SPECIAL PROGRAM MODE

Review Usage
1.

Press and hold the FUNCTION button for two seconds until
“REG PROGRAM” shows in the display. As soon as
“REG PROGRAM” shows in the display, press and release
the FUNCTION button 1 time until “REVIEW USE” shows
in the display.

2.

“DAILY” shows in the display. Press any of the product
buttons to view the usage of that product. Press and hold the
FUNCTION button to exit Special Program mode.

Reset Usage
1.

Press and hold the FUNCTION button for two seconds until
“REG PROGRAM” shows in the display. As soon as “REG
PROGRAM” shows in the display, press and release the
FUNCTION button 2 times until “RESET USE” shows in
display.

2.

When “CODE” shows in the display, press 1-3-5. “DAILY
will show in the display, and press any of the Product buttons
to reset them to 0.