Henny Penny OFE- 290 User Manual

Page 20

Advertising
background image

Model OFE- 290

3-16. SPECIAL PROGRAM

Heat Control

MODE (Continued)

1.

Press and hold the FUNCTION button for two seconds until
“REG PROGRAM” shows in the display. As soon as
“REG PROGRAM” shows in the display, press and release
the FUNCTION button 6 times until “HEAT CNTRL” shows
in the display.

2.

When “CODE” shows in the display, press 1-2-3-4.
“MELT”, “EXIT”, and “TEMP” flashes in the display, along
with the shortening temperature at which the unit will exit the
melt cycle. This should be set at 180

º

F (82

º

C), and should

not be changed until the factory is consulted.

3.

Press and release the FUNCTION button and ”MELT”,
“CYCLE”, and “100s” shows alternately in the display, along
with the period (pulse) length of 4000. This should not be
changed until the factory is consulted.

4.

Press and release the FUNCTION button twice and
“MELT”, “ON-”, “TIME”, and “100s”, shows alternately in
the display, along with the length of time the heat is on. This
should be set at 1700, and should not be changed until the
factory is consulted.

5.

Press and release the FUNCTION button three times and
“COOL”, “SET-”, and “POINT” shows alternately in the
display, along with the temperature at which the control exits
the melt cycle. This is set at 250

º

F (121

º

C), and should not

be changed until the factory is consulted.

6.

Press and release the FUNCTION button four times and
“AUTO”, and “IDLE” shows alternately in the display, along
with “OFF”. This should not be changed until the factory is
consulted.

7.

Press and release the FUNCITON button five times and
“AUTO”, “IDLE”, and “MMSS” shows alternately in the
display, along with “0:00”. This should not be changed until
the factory is consulted.

8.

The last 3 functions in the Heat Control Mode are used by the
factory only, and should not be changed.

3-20

703

Advertising