Hyundai HX300L User Manual

Page 115

Advertising
background image


6. Trobleshooting



6-9

6.3.5. Encoder


Position offset, malfunction, and out of control movement as well as staggering at
stop, irregular twitching may occur when the Encoder is in bad condition. This case
has nothing to do with such phenomena as mechanical abnormal sound, overheating,
and vibration

Diagnostics

① Check for any encoder data failure.
② Use reference pins and blocks to check the positional data is correct at

pin position.

③ Check for any irregular variations in the encoder data when moving each

robot axis.

④ Replace the servo amp board, BD440 to check errors.

Resolution

① If cabling turns out to be in good condition withouth any damage, replace

the encoder.

② If there is no error after replacing the servo amp board BD440, replace the

servo amp board.


Advertising
This manual is related to the following products: