HX200/HX200L-2000/HX300/HX300L/HX400



1-10

1.6.2. Placement of Robot & Peripheral Equipment


(1) Make sure that the power supply is off before operating, when connecting the

primary power of controller or peripheral equipment. There is a possible
danger of electric shock because the high voltage such as 220V and 440V is
used as its primary power.


(2) Post a sign [No enter during operation] up the safety fence gate, and inform

the operators of its purport.

Interlocked Barrier Guard

11

0 c

m

(4

4")

M

in

Restricted

space

Maximum

space

110 cm(44") Min

11

0

cm

(4

4"

) M

in

Operator

Safeguarded
space

Controller

Fig 1.3 Placement of Peripheral Equipment and Operator

(3) Arrange

such devices as controller, interlock panel, and other manipulation

panels to be handled outside of the safety fence.


(4) When installing operation stand, install the emergency stop button on the

stand. Make sure that the stand stops in an emergency wherever the robot is
handled.