HX200/HX200L-2000/HX300/HX300L/HX400



1-28

(2) Emergency stop of external system

External emergency stop device (button etc.) can be connected to the safety
electric circuit in accordance with applied standard for the emergency stop
circuit.

▶ Emergency stop connection of the external system

EMST2C

EMST1C

EMST2B

EMST2A

EMST2C

EMST1C

Emergency Stop Switch

EMST2B

EMST1B

CNTPS

CNOP

M1

P1

EMST1A

EMST1B

EM_STOP2

CNRTP

M

N

K

L

EMST2C

EMST1C

E

S

1

E

S

2

RUN CHAIN

ESOUT1

TBEXT:5

ESOUT2

TBEXT:6

M1(0V)

P1(24V)

M1(0V)

P1(24V)

TBEXT:1

TBEXT:2

TBEXT:4

TBEXT:3

EXTERNAL SYSTEM
Emergency Stop Switch

A2

B2

TEACHING PENDANT

OPERATIONAL PANEL
Emergency Stop Switch

SEQUENCE BOARD(BD461)

EM_STOP1

CNOP:19

CNOP:20

A1

B1

CNOP:17

CNOP:18

EMST2A

EMST2B

EMST1A

EMST1B

Emergency Stop Channel 1 LED

Emergency Stop Channel 2 LED

Fig 1.7 Emergency Stop Connection of External System

※ When using the emergency stop of the external system, connect the Terminal No.

1 (ES1) & No. 2 (M1,0V Common) or No. 3 (ES2) & No. 4 (P1,24V Common) of
the terminal block of BD461 to the external emergency stop line, and you must
open JP1 or JP2.

At this time, the emergency stop must be connected to be Normal On and it must
be check for proper operation during test run.



JP1