6.

Power on the enclosure.

7.

Power on the server.

SAS Cable Part Numbers

If you require additional cables, order them by the option kit number listed in

Table 3-16

.

Table 3-16 SAS Cable Part Numbers

Cable Assembly Number

Option Kit Number

Cable Length

361317-001

389664-B21

1.0 m (3.3 ft.)

361317-002

389668-B21

2.0 m (6.6 ft.)

361317-004

389671-B21

4.0 m (13 ft.)

361317-006

389674-B21

6.0 m (20 ft.)

SAUPDATE Utility

Use saupdate from the EFI Shell to update the firmware image on the HP Smart Array Controller.
Command line options are described below. Follow one of these two procedures to run saupdate:.

If you are using saupdate from the Offline Diagnostic CD:

1.

Download the firmware and copy it to the EFI partition.

2.

The CD containing saupdate.efi must be in the drive before booting the system to allow
device mapping.

3.

Boot the system to the EFI Shell prompt. The CD drive should appear in the list of mapped
devices as fs0.

4.

Change to this device by typing fs0: under EFI Shell prompt.

5.

If the EFI utility and firmware image files are not located in the root directory, move to the
directory in which these files are located, for example:

fs0: >cd  EFI HP TOOLS IO_CARDS SmartArray

IMPORTANT:

Both saupdate.efi and the firmware image file must be located in the same

directory. If they are not, copy them both to the EFI partition. Run the saupdate.efi using the
fs0: > saupdate

command.

If you are not using the Offline Diagnostic CD:

1.

Download the SA EFI update utility saupdate.efi and copy it to the EFI partition.

2.

Download the firmware and copy it to the EFI partition.

3.

Boot the system to the EFI Shell and change directories to the EFI partition.

4.

Run the saupdate.efi using the using the fs0:\> saupdate.efi command.

The following screen displays. The version of the utility displays on the second line:

*************************************************************
Smart Array Offline Firmware Update Utility
Version: 1.04.12.00

(C) Copyright 2004 Hewlett Packard Development Company L.P.
*************************************************************

Syntax

saupdate <operation> <parameters>

Commands

You can use the following operations with saupdate:

110