00 00 02 00 0x1033 0x0035 XX Acpi(HWP0002,PNP0A03,0)/Pci(2|0)
00 00 02 01 0x1033 0x0035 XX Acpi(HWP0002,PNP0A03,0)/Pci(2|1)
00 00 02 02 0x1033 0x00E0 XX Acpi(HWP0002,PNP0A03,0)/Pci(2|2)
00 14 01 00 0x1000 0x0054 01 Acpi(HWP0002,PNP0A03,400)/Pci(1|0)
00 14 02 00 0x1000 0x0054 02 Acpi(HWP0002,PNP0A03,400)/Pci(2|0)
00 15 01 00 0x1000 0x000F 07 Acpi(HWP0002,PNP0A03,500)/Pci(1|0)
00 15 01 01 0x1000 0x000F 07 Acpi(HWP0002,PNP0A03,500)/Pci(1|1)
00 15 02 00 0x8086 0x1079 08 Acpi(HWP0002,PNP0A03,500)/Pci(2|0)
00 15 02 01 0x8086 0x1079 08 Acpi(HWP0002,PNP0A03,500)/Pci(2|1)

Fast initialization: Enabled
System Wake-On-LAN: Enabled

Shell>

Devices, such as USB ports, that do not occupy a slot are referenced as being in slot XX. Slots
that do not contain an I/O card will not be listed in the output. Using the output, confirm
that a device detected in each slot that is populated.

13. Installing the OS

HP-UX, Windows, and Linux require reinstallation of the OS with the upgrade of the IOBP.
See

Figure B-1 (page 262)

for more information.

14. Booting to the Operating System

See

Chapter 4 (page 123)

for this procedure.

Installing Core I/O Cards

WARNING!

To reduce the risk of personal injury from hot surfaces, allow the internal system

components to cool before touching them.

CAUTION:

To reduce the risk of personal injury or damage to the equipment, consult the safety

information and user documentation provided with the server before attempting the installation.
Many servers are capable of producing energy levels that are considered hazardous and are
intended to be serviced only by qualified personnel who have been trained to deal with these
hazards. Do not remove enclosures or attempt to bypass any interlocks that may be provided
for the purpose of removing these hazardous conditions.

CAUTION:

Electrostatic discharge (ESD) can damage electronic components. Be sure that you

are properly grounded before beginning this procedure.

CAUTION:

When working with equipment installed in a rack, be sure that the equipment and

rack are stable before beginning the installation procedure.

Slots 1 and 2 are dedicated for the PCI-X core I/O cards. The LAN core I/O card is installed either
in slot 2 or slot 10 depending on the configuration. PCIe SAS core I/O cards are installed in slots
3 or 4 on the PCIe I/O backplane.
Cabling

The cables that are required to connect the adapters and controllers to other devices

are provided with most HP server products that need them.

Table B-3

lists some cables that can

be used with these adapters and controllers. All HP cables are keyed so that they cannot be
installed incorrectly.

Table B-3 Cable kit part numbers

Part Number

Description

Type of Cable

389647-B21

Multi-lane A cable

Internal SAS/SATA

389650-B21

Host fan cable

Internal SAS/SATA

389653-B21

Target fan cable

Internal SAS/SATA

389659-B21

Multi-lane B cable

Internal SAS/SATA