Table 5-22 Cooling Subsystem Events that Light Diagnostic Panel LEDs

Notes

Source

Cause

IPMI Events

Diagnostic
LEDs

Replace the fan.

BMC

The fan has failed or
is degrading.

Type 02h, 0Ah:07h:01h
COOLING_UNIT_WARNING

Fans (1-3)

Replace the fan.

BMC

The fan has failed
and no longer meets
minimum cooling
requirements.

Type 02h, 0Ah:07h:02h
COOLING_UNIT_FAILURE

Fans (1-3)

Common I/O Backplane

This subsection provides information on troubleshooting issues with the eight public and two
private PCI-X slots.

I/O Subsystem Behavior

The I/O subsystem transfers blocks of data and instruction words between physical shared
memory and virtual memory (system disks/disk array). The system boot is the first time blocks
of data and instructions words are transferred into physical shared memory from a local disk or
DVD or from a remote disk on another server using multiple LAN transfers. This process is
referred to as Direct Memory Access (DMA). It is initiated by I/O devices located in core I/O or
on Host Bus Adapter (HBA) I/O cards and does not involve any logical CPUs.

The I/O subsystem also transfers data between the internal registers within each CPU core and
the internal control registers within the Zx2/PDH/Local Bus Adapters (LBA) and HBA chips.
This process is referred to as programmed I/O. It is initiated by logical CPUs executing external
LOAD/STORE instructions. Both system firmware and the OS kernel use this method to initiate
DMA transfers.)

I/O Messages

Use the SEL to identify low level I/O subsystem faults if LEDs on the diagnostic panel are
not lit. IPMI events in the SEL and FPL provide the logical ACPI path of the suspect I/O
subsystem CRU. To determine the physical PCI slot number, see

Table 5-25

.

For configuration errors, for example, no core I/O HBAs installed or working, see

“Supported

Configurations” (page 155)

.

Diagnostic messages are reported for high level I/O subsystem errors. All fatal I/O subsystem
errors cause global MCAs. HP-UX provides its own path with the physical rope number of
the suspect I/O subsystem CRU. To determine the physical PCI slot number, see

Table 5-25

.)

Table 5-23

and

Table 5-24

lists the I/O card events that light and may light the diagnostic panel

LEDs.

Table 5-23 I/O Card Events that Light Diagnostic Panel LEDs

Notes

Source

Cause

IPMI Events

Diagnostic
LEDs

Possible short circuit on
the I/O card or I/O slot.

BMC

Overcurrent on PCI
slot.

Type 02h, 03h:05h:01h
CURRENT_LIMIT_EXCEEDED

I/O card

A voltage on the I/O
backplane is out of range
(probably too low).

BMC

The voltage on the
CRU is inadequate.

Type 02h, 02h:07h:03h
VOLTAGE_DEGRADES_TO_NON_RECOVERABLE

I/O assembly

A voltage on the I/O
backplane is out of range
(probably too low).

BMC

The voltage on the
CRU is inadequate.

Type 02h, 02h:07h:03h
VOLTAGE_DEGRADES_TO_NON_RECOVERABLE

Disk
assembly

Common I/O Backplane

167

Advertising