Battery Connections
Use the following materials to connect a 12-volt battery to the starter
on TYPE 7 units (electric start with engine-mounted starter switch/
manual choke control/preset throttle):
Battery – 12-volt lead acid battery with a recommended ampere-hr

rating of 3 Ah or a 14.4-volt NiCd battery with a recommended
ampere-hr rating of 1.7 Ah.

Wire – 12-gauge (minimum) wire with a maximum length of 10 ft

(3 meters).

Fuse – 40-ampere blade type fuse.
Terminal – Delphi 56 series male connector and terminal to

connect to the starter motor.

Coat the battery terminals and cable ends with dielectric grease. Be
careful not to connect the battery in reverse polarity.

WARNING: Battery posts, terminals and related accessories contain
lead and lead compounds. Wash hands after handling.

1. Connect the battery positive (+) cable using the appropriate

connector and insulator to the supplied starter connector.

2. Connect the battery negative (-) cable to an engine mounting bolt,

frame bolt, or the provided ground position on the starter motor
(requires 5 x 8 mm screw).

3. Connect the battery positive (+) cable to the battery positive (+)

terminal as shown.

4. Connect the battery negative (-) cable to the battery negative (-)

terminal as shown.
The following diagram only shows connections for TYPE 7 units
(electric start with engine-mounted starter switch/manual choke
control/preset throttle). Connections are different for the other
electric starter types (TYPES 4 and 6).

This engine is not equipped with a charging system to keep the
battery charged during engine operation. The battery will loose
charge during starter motor operation only. There is no drain on the
battery once the engine is running.

The battery must be charged by an external battery charging system.
Refer to the equipment manufacturer’s instructions or the battery
manufacturer for specific external battery charging recommendations.

Wiring Diagrams

WARNING

A battery can explode if you do not follow the correct
procedure, seriously injuring anyone nearby.

Keep all sparks, open flames, and smoking materials away
from the battery.

BATTERY
NEGATIVE (-)
CABLE

BATTERY
NEGATIVE (-)
TERMINAL

BATTERY

BATTERY POSITIVE
(+) TERMINAL

STARTER
MOTOR

40 AMP FUSE

STARTER MOTOR
POSITIVE (+) CONNECTOR
(from starter switch)

STARTER GROUND (-)
CONNECTION

BATTERY POSITIVE (+)
CABLE

IGNITION
COIL

SPARK
PLUG

ENGINE STOP
SWITCH

RECOIL STARTER
(All Types)

IGNITION
COIL

SPARK
PLUG

STARTER
MOTOR

STARTER
SWITCH

FUSE
(40A)

ELECTRIC STARTER
(TYPE 6 with Blade Brake Clutch)

Supplied by equipment
manufacturer.

BATTERY

ENGINE STOP
SWITCH

SPARK
PLUG

STARTER
SWITCH

BATTERY

IGNITION
COIL

ELECTRIC STARTER
(TYPE 4 with Flywheel Brake)

FUSE
(40A)

STARTER
MOTOR

Supplied by equipment
manufacturer.

SPARK
PLUG

STARTER
MOTOR

STARTER
SWITCH

FUSE
(40A)

BATTERY

ELECTRIC STARTER
(TYPE 7 with Starter Switch on the engine)

Supplied by equipment
manufacturer.

STARTER SWITCH

IGNITION
COIL

POM52684-L.book Page 12 Monday, February 5, 2007 3:00 PM