Your PC Workstation Does Not Start Correctly

Case 4 — Boot Process Fails

Runtime Errors

During normal usage (and at boot) of the PC Workstation, MaxiLife
continually monitors vital system parameters. These include:
temperature, fan malfunctions, power voltage drops, system board PLL
problems and CPU problems.

Refer to page 13 for pre-boot MaxiLife error screens.

Test

Error Code

Action to Take

Check in the order given, the connection of the

corresponding component, which could be:

During normal usage of the PC, HP MaxiLife continually
checks vital system parameters. If an error should occur, a
message would be automatically displayed on the LCD panel.

FAN CPU

Rear fan, system board, fan cable.

FAN PCI

PCI Fan, PCI cards, system board, fan cable.

TEMP. CPU

Rear fan, airflow guide, “Airflow Separator

1

”, system board.

TEMP. PCI

PCI fan, “Airflow Separator” Airflow guide, system board,
PCI cards.

TEMP. DISK

Rear fan, Airflow guide, “Airflow Separator”, Temp Disk
sensor, system board.

POWER
ERRORS

Power supply unit, VRM, system board.

BAD PLL

Processor(s), system board.

1.

A retaining bar holds the airflow separator in place, dividing inside the chassis into two separate areas (processor and PCI slot)
for better cooling.