Venting with one (1) 90° elbow, Venting with two (2) 90° elbows – Heat & Glo Fireplace 7000XLS User Manual

Page 10

Advertising
background image

14

V

H

1' MIN. (305mm)

2' MAX. (610mm)

2' MIN. (610mm)

4' MAX. (1.22m)

3' MIN. (914mm)

6' MAX. (1.86m)

4' MIN. (1.22m)

8' MAX. (2.4m)

V+H=40' MAX. (12.4m) H = 8' MAX. (2.4m)

NOTE: On vertical venting configurations

where the vertical component is over 10

feet, you may want to install the vertical

baffle included in the manual bag assembly

to improve flame appearance.

Figure 7. Venting with One 90° Elbow

VENTING WITH ONE (1) 90° ELBOW

Figure 8. Venting with Two 90° Elbows

VENTING WITH TWO (2)

90° ELBOWS

V

H

H + H

1

1´ MIN. (305 mm)

2´ MAX. (610 mm)

6´ MAX. (1.82m)

2´ MIN. (610 mm)

4´ MAX. (1.22 m)

12´ MAX. (3.65m)

3´ MIN. (914 mm)

6´ MAX. (1.86 m)

18´ MAX. (5.48m)

4´ MIN. (1.22 m)

8´ MAX. (2.48 m)

24´ MAX. (7.31m)

V+H+H

1

= 40´ MAX. (12.4 m) H = 8´ MAX. (2.48 m) H+H

1

= 24´ MAX. (7.31m)

Advertising
This manual is related to the following products: