17

2. Continue Adding Vent Components

WARNING: INSTALLATION OF THE 7000XLS

FIREPLACE REQUIRES THE USE OF HEAT

SHIELD 570-290 ABOVE THE FIRST 90

0

ELBOW IN

THE VENTING SYSTEM THAT MAKES A TRANSI-

TION FROM VERTICAL TO HORIZONTAL. (HEAT

SHIELD NOT REQUIRED FOR 6000XLSB).

Figure 11

To Install the Heat Shield:
1. Determine if the heat shield is required. Do so by mea-

suring the vertical distance between the top horizontal

surface of the elbow to any combustible surface above.

If the distance is more than 4 inches, the heat shield is

NOT required. If it is 4 inches or less, the heat shield IS

REQUIRED. Install per the following steps. See Figure 11.

!

• Continue adding vent components, locking each succeed-

ing component into place.

• Ensure that each succeeding vent component is secure-

ly fitted and locked into the preceding component in the

vent system.

• 90° elbows may be installed and rotated to any point

around the preceding component’s vertical axis. If an el-

bow does not end up in a locked position with the pre-

ceding component, attach with a minimum of two (2)

sheet metal screws.

Figure 12

CORRECT

INCORRECT

2. Fasten the shield in place using the four pilot holes pro-

vided in the part. The shield should be oriented such that

the 13 1/8 inch dimension (longest dimension) is run-

ning in the same direction the elbow is pointing. The

shield should be centered directly above the elbow, and

positioned so that it creates a 1/2 inch airspace between

the shield and the combustible surface. See Figure 12.

3. Install Support Brackets
For Horizontal Runs -
The vent system must be supported

every five (5) feet of horizontal run by a horizontal pipe support.
To install support brackets for horizontal runs:
• Place the pipe supports around the vent pipe.
• Nail the pipe supports to the framing members.

Figure 13. Adding Venting Components

Advertising
This manual is related to the following products: