Heat & Glo Fireplace 7000XLS User Manual

Page 16

Advertising
background image

20

!

C. Vent Termination

For Horizontal Terminations - To attach and secure the

termination to the last section of horizontal vent:
• Rotate and interlock the ends as described at the begin-

ning of the Installing Vent Components section.

• The termination kit should pass through the wall firestops

from the exterior of the building.

• Adjust the termination cap to its final exterior position on

the building.

WARNING: THE TERMINATION CAP MUST BE

POSITIONED SO THAT THE ARROW IS

POINTING UP.

For roundcap termination kits:
• Use the exterior pipelock hole on the round flange of the

wall firestop to secure the vent pipe in place.

For trapezoidal cap termination kits:
• Using screws secure the cap to the exterior wall through

the flanges in the cap.

Figure 20. Round & Trapezoid Termination Caps

!

WARNING: THE BOTTOM OF THE VENT

TERMINATION CAP MUST BE A MINIMUM

OF 12 INCHES (305 MM) ABOVE GROUND LEVEL

(GRADE). THE TOP OF THE CAP MUST BE A MIN-

IMUM OF 18 INCHES (457 MM) BELOW COMBUS-

TIBLE MATERIAL, SUCH AS A DECK. THE SIDE

OF THE CAP MUST BE A MINIMUM OF 6 INCHES

(152 MM) AWAY FROM A PARALLEL OUTSIDE

WALL. VENTING TERMINALS SHALL NOT BE RE-

CESSED INTO A WALL OR SIDING. SEE THE FOL-

LOWING DIAGRAM FOR VENT TERMINATION

CLEARANCES.

ROUND CAP TERMINATION

PERFORATION CANNOT BE

INSIDE THE WALL

7 1/2"

(191mm)

MINIMUM

TRAPEZOID CAP TERMINATION

7 1/4"

(184mm)