Step 9. finishing – Heat & Glo Fireplace 7000XLS User Manual

Page 22

Advertising
background image

26

Step 9. Finishing

Figure 28 shows the minimum vertical and corresponding

maximum horizontal dimensions of fireplace mantels or other

combustible projections above the top front edge of the

fireplace. See Figures 2 and 3 for other fireplace clearances.
Only non-combustible materials may be used to cover the

black fireplace front.

WARNING: WHEN FINISHING THE FIREPLACE,

NEVER OBSTRUCT OR MODIFY THE AIR IN-

LET/OUTLET GRILLES IN ANY MANNER.

!

Figure 28.

Minimum Vertical and Maximum Horizontal

Dimensions of Combustibles above Fireplace

CAUTION: IF JOINTS BETWEEN THE FINISHED WALLS

AND THE FIREPLACE SURROUND (TOP AND SIDES)

ARE SEALED, A 300°

F. MINIMUM SEALANT MATE-

RIAL MUST BE USED. THESE JOINTS ARE NOT RE-

QUIRED TO BE SEALED. ONLY NON-COMBUSTIBLE

MATERIAL (USING 300° F. MINIMUM ADHESIVE, IF

NEEDED) CAN BE APPLIED AS FACING TO THE FIRE-

PLACE SURROUND. SEE THE DIAGRAM BELOW.

Hearth Extensions

A hearth extension may be desirable for aesthetic reasons.

However, ANSI or CAN/CGA testing standards do not require

hearth extensions for gas fireplace appliances.

Figure 29. Sealant Material

HIGH TEMPERATURE

SIDE SEAL JOINT

(300 F/149 C MIN.)

TOP &

O

O

0

0

FINISH WALL MATERIAL MAY BE DRYWALL

- TOP AND SIDES

0

2”

4"

5”

6”

7”

8”

9”

2"

3"

4"

5"

12"

11"

10"

9"

8"

7"

6"

TOP FRONT EDGE

OF FIREPLACE

3”

11”

12”

10”

31”

CEILING

Advertising
This manual is related to the following products: