V ft. h + h, Ft.), Venting with two (2) 90 – Heat & Glo Fireplace 36DV User Manual

Page 14: Elbows

Advertising
background image

14

VENTING WITH ONE (1) 90° ELBOW

V (FT.)

H (FT.)

1.5' MIN. (.457m)

2.5' MAX. (.762m)

2' MIN. (.609m)

3' MAX. (.912m)

2.5' MIN. (.762m)

6' MAX. (1.82m)

3.5' MIN. (1.06m)

9' MAX. (2.73m)

4.5' MIN. (1.37m)

12' MAX. (3.64m)

5.5' MIN. (1.67m)

15' MAX. (4.55m)

6.5' MIN. (1.98m)

18' MAX. (5.46m)

7.5' MIN. (2.28m)

21' MAX. (6.37m)

8.5' MIN. (2.59m)

24' MAX. (7.28m)

V = 40’ MAX. (12.2m)
V+H = 64’ MAX. (19.5m) H = 24' MAX. (7.28m)

Figure 11.
Venting with One 90° Elbow

NOTE: Must have a 12”
minimum vertical vent
before attaching a 90

o

elbow to the unit.

H

V

Figure 12. Venting with Two 90° Elbows

V FT.

H + H

1

(FT.)

1.5' MIN.

(.457m)

2.5´ MAX. (.762m)

2' MIN.

(.609m)

3´ MAX. (.912m)

2.5' MIN.

(.762m)

6´ MAX. (1.82m)

3.5' MIN.

(1.06m)

9’ MAX. (2.73m)

4.5' MIN.

(1.37m)

12´ MAX. (3.64m)

V+H+H

1

= 64' MAX.(19.5m) H+H

1

= 24´ MAX. (7.3m)

V+V

1

+H

= 64' MAX.(19.5m)

VENTING WITH

TWO (2) 90

o

ELBOWS

H

V

V

V

1

H

H

1

H

V

NOTE: Must have a 12”
minimum vertical vent
before attaching a 90

o

elbow to the unit.