Heat & Glo Fireplace 36DV User Manual

Page 15

Advertising
background image

15

VENTING WITH THREE (3) 90° ELBOWS

V (FT.)

H

(FT.)

1.5' MIN. (.457m)

2.5' MAX. (.762m)

2' MIN. (.609m)

3' MAX. (.912m)

2.5' MIN. (.762m)

6' MAX. (1.82m)

3.5' MIN. (1.06m)

9' MAX. (2.73m)

4.5' MIN. (1.37m)

12' MAX. (3.64m)

NOTE: H + H

1

= 24' MAX. (7.28m)

V + V

1

+ H + H

1

= 64' MAX. (19.5m)

V (FT.)

H + H

1

(FT.)

1.5' MIN. (.457m)

2.5' MAX. (.762m)

2' MIN. (.609m)

3' MAX. (.912m)

2.5' MIN. (.762m)

6' MAX. (1.82m)

3.5' MIN. (1.06m)

9' MAX. (2.73m)

4.5' MIN. (1.37m)

12' MAX. (3.64m)

H +H

1

= 20' MAX. (6.2m)

NOTE:

V+V

1

+H +H

1

= 64' MAX. (19.5m)

Figure 13. Venting with three 90° elbows

V

H

H

1

V

1

V

H

H

1

V

1

NOTE: Must have a 12”
minimum vertical vent
before attaching a 90

o

elbow to the unit.