Step 10. Finishing

Figure 26 shows the minimum vertical and corresponding
maximum horizontal dimensions of fireplace mantels or other
combustible projections above the opening edge of the
fireplace. See Figures 2 and 3 for other fireplace clearances.

Only non-combustible materials may be used to cover the
fireplace front.

WARNING: WHEN FINISHING THE FIREPLACE,
NEVER OBSTRUCT OR MODIFY THE AIR IN-
LET/OUTLET GRILLES IN ANY MANNER.

!

Figure 26.
Minimum Vertical and Maximum Horizontal
Dimensions of Combustibles above Fireplace

CAUTION: IF JOINTS BETWEEN THE FINISHED WALLS
AND THE FIREPLACE SURROUND (TOP AND SIDES)
ARE SEALED, A 300°

F. MINIMUM SEALANT MATE-

RIAL MUST BE USED. THESE JOINTS ARE NOT RE-
QUIRED TO BE SEALED. ONLY NON-COMBUSTIBLE
MATERIAL (USING 300° F. MINIMUM ADHESIVE, IF
NEEDED) CAN BE APPLIED AS FACING TO THE FIRE-
PLACE SURROUND. SEE THE DIAGRAM BELOW.

Figure 27. Sealant Material

!

WARNING: A 12” minimum hearth extension
is required to protect combustible floor con-

struction in front of the fireplace in certain instal-
lations. This hearth must be constructed of non-
combustible material and extend the width of the
fireplace (see Figures 4 and 5).

HIGH TEMPERATURE (300

0

F /149

0

C MIN.)

TOP & SIDES SEAL JOINT

HIGH TEMPERATURE (300

0

F /149

0

C MIN.)

TOP SEAL JOINT

3-1/2”

36”

11-1/2”

12”

8”

4”

12”

11”

10”

9”

8”

7”

6”

5”

4 ”

3”

2”

1”

Height above opening

Horizontal Mantle distance

4"

1"

5"

2-1/4"

6"

3-1/2"

7"

4-3/4"

8"

6"

9"

7-1/2"

10"

9"

11"

10-1/2"

12"

12"