Minimum Clearances

from the Fireplace to Combustible Materials

Inches

mm

Glass Sides or Ends .......... 36 .................... 914

Floor ................................... 0 ....................... 0
Rear Vent ........................... 1/2 ..................... 13
Metal Sides or Ends .......... 1/2 ..................... 13
Top ................................... 2 1/2 ................... 64

Ceiling* .............................. 31 .................... 787

For minimum clearances, see the direct vent termination
clearance diagrams on pages 31 and 32 in this manual.

Minimum Clearances

from the Vent Pipe to Combustible Materials

Inches

mm

Vertical Sections. ............. 1 ................ 25

Horizontal Sections

Top ..................................... 3 ................ 75

Bottom ............................... 1 ................ 25

Sides ................................. 1 ................ 25

At Wall Firestops

Top .................................. 2 1/2 ............ 63.7

Bottom .............................. 1/2 ............... 13

Sides ................................. 1 ................ 25

* The clearance to the ceiling is measured from the top of

the unit, excluding the standoffs (see Figures 37 & 38).

The distance from the unit to combustible construction is to
be measured from the unit outer wrap surface to the com-
bustible construction, NOT from the screw heads that se-
cure the unit together.

!

WARNING: FRAMING DIMENSIONS ASSUME
USE OF 1/2 INCH THICK WALL COVERING

MATERIALS ON EXTERIOR OF FRAMING ONLY AND
NO SHEETROCK ON INTERIOR OF FRAMING.

Step 2. Framing the Fireplace

Fireplace framing can be built before or after the fireplace is
set in place. Framing should be positioned to accommo-
date wall coverings and fireplace facing material. The dia-
gram below shows framing reference dimensions.

CAUTION: MEASURE FIREPLACE DIMENSIONS AND
VERIFY FRAMING METHODS AND WALL COVERING
DETAILS BEFORE FRAMING.