29

Figure 19. Venting with three 90° elbows

V

H

H

1

V

1

V

H

H

1

V

1

NATURAL GAS

VENTING WITH THREE 90° ELBOWS

V + V

1

(FT.)

H + H

1

(FT.)

90

0

Elbow on top 2.5’ MAX. (64mm)

1' MIN. (305mm)

3' MAX. (914mm)

2' MIN. (610mm)

6' MAX. (1.83m)

3' MIN. (914mm)

9' MAX. (2.7m)

4' MIN. (1.22m)

12' MAX. (3.6m)

5’ MIN. (1.5m)

15’ MAX. (4.5m)

6’ MIN. (1.83m)

18’ MAX. (5.5m)

V+ V

1

+ H + H

1

= 50’ MAX. (15.2m)

PROPANE

VENTING WITH THREE 90° ELBOWS

V + V

1

(FT.)

H + H

1

(FT.)

90

0

Elbow on top 2’ MAX. (610mm)

1' MIN. (305mm)

2' MAX. (610mm)

2' MIN. (610mm)

4' MAX. (1.22m)

3' MIN. (914mm)

6’ MAX. (1.83m)

4' MIN. (1.22m)

8' MAX. (2.4m)

5’ MIN. (1.5m)

10' MAX. (3.0m)

6’ MIN. (1.83m)

12' MAX. (3.6m)

V+ V

1

+ H + H

1

= 50’ MAX. (15.2m)

H + H

1

= 12’ MAX. (3.6m)

H + H

1

= 18’ MAX. (5.5m)