Step 8. Wiring the Fireplace

NOTE: Electrical wiring must be installed by a licensed
electrician.

CAUTION: DISCONNECT REMOTE CONTROLS IF AB-
SENT FOR EXTENDED TIME PERIODS. THIS WILL PRE-
VENT ACCIDENTAL FIREPLACE OPERATION.

For Intermittent Pilot Ignition Wiring

Appliance Requirements

This appliance requires that 110-120 VAC be wired to the
junction box. Maintain correct polarity when wiring the junc-
tion box.

Figure 34. Intermittent Pilot Ignition
(IPI) Wiring Diagram

Operation using Battery Power

This fireplace has an optional battery operation. The sys-
tem is fully functional with the use of two “D” size batteries
without ordinary 110-120 VAC power.

Wiring to the battery pack should be left disconnected in
order to conserve battery life. In the case of a loss of power,
simply connect red and black wire leads to activate battery
power (connect red to red, black to black). The fireplace can
be used as necessary. Once power (110 VAC) is restored,
disconnect red and black wire leads to extend battery life.

WARNING

Wire 110V to electrical junction box.
Do NOT wire 110V to valve.
Do NOT wire 110V to wall switch.
• Incorrect wiring will damage millivolt valves.

• Uninterrupted or continuous power is required at all times

in IPI system EXCEPT when using battery back-up.

• Incorrect wiring will override IPI safety lockout and may

cause explosion.

IGNITION
MODULE

(3V)

VALVE

LOW VOLTAGE

PLUG-IN

3V TRANSFORMER

NEUTRAL

HOT

GROUND

FLAME SPARKER/

SENSOR

REMOTE

CONTROL

SEE NOTE 1

IGNITION MODULE 3 VAC

INTERMITTENT
PILOT IGNITOR

GROUND TO
FIREPLACE
CHASSIS

VALVE

TRANSFORMER 3 VAC

ORG

WHT

OR

G

GR

N

WH

T

ON/OFF

WALL SWITCH

BR

N

BR

N

BL

K

WH

T

BLK

WHT

BL

K

WHT

BL

K

TERMINAL BLOCK

BULB SOCKET
ASSEMBLY (3)

FLAME ON/OFF

PLUG IN

BLACK WIRE CAN BE

PLUGGED INTO ANY OF

#1 - #5 LOCATIONS

ON THE HOT SIDE

WHITE WIRE
CAN BE
PLUGGED
INTO ANY
OF #1 - #5
LOCATIONS
ON THE
NEUTRAL
SIDE

SCALE 1/1

LCOR & RCOR JUNCTION BOX

S

I

ELECTRONIC EMBERS

ELECTRIC EMBERS

Note: An alternate electric ember
switch can be installed on the wall
by connecting a minimum 14 gage
Romex

to the leads supplied on

the back of the electric ember
switch.

WARNING

Shock Hazard

Disconnect 110V before servicing.

• Electric ember lighting uses 110V.