Figure 15. Venting with Two 90° Elbows

H

1

H

V

V

V

1

H

NATURAL GAS

VENTING WITH TWO 90° ELBOWS

V (FT.)

H + H

1

(FT.)

90

0

Elbow on top 2.5’ MAX. (64mm)

1' MIN. (305mm)

3' MAX. (914mm)

2' MIN. (610mm)

6' MAX. (1.83m)

3' MIN. (914mm)

9' MAX. (2.7m)

4' MIN. (1.22m)

12' MAX. (3.6m)

5’ MIN. (1.5m)

15’ MAX. (4.5m)

6’ MIN. (1.83m)

18’ MAX. (5.5m)

V + H + H

1

= 50’ MAX. (15.2m)

PROPANE

VENTING WITH TWO 90° ELBOWS

V (FT.)

H + H

1

(FT.)

90

0

Elbow on top 2’ MAX. (610mm)

1' MIN. (305mm)

2' MAX. (610mm)

2' MIN. (610mm)

4' MAX. (1.22m)

3' MIN. (914mm)

6’ MAX. (1.83m)

4' MIN. (1.22m)

8' MAX. (2.4m)

5’ MIN. (1.5m)

10' MAX. (3.0m)

6’ MIN. (1.83m)

12' MAX. (3.6m)

V + H + H

1

= 50’ MAX. (15.2m)

NATURAL GAS

VENTING WITH TWO 90° ELBOWS

V + V

1

(FT.)

H (FT.)

90

0

Elbow on top 2.5’ MAX. (64mm)

1' MIN. (305mm)

3' MAX. (914mm)

2' MIN. (610mm)

6' MAX. (1.83m)

3' MIN. (914mm)

9' MAX. (2.7m)

4' MIN. (1.22m)

12' MAX. (3.6m)

5’ MIN. (1.5m)

15’ MAX. (4.5m)

6’ MIN. (1.83m)

18’ MAX. (5.5m)

V + V

1

+ H = 50’ MAX. (15.2m)

PROPANE

VENTING WITH TWO 90° ELBOWS

V + V

1

(FT.)

H (FT.)

90

0

Elbow on top 2’ MAX. (610mm)

1' MIN. (305mm)

2' MAX. (610mm)

2' MIN. (610mm)

4' MAX. (1.22m)

3' MIN. (914mm)

6’ MAX. (1.83m)

4' MIN. (1.22m)

8' MAX. (2.4m)

5’ MIN. (1.5m)

10' MAX. (3.0m)

6’ MIN. (1.83m)

12' MAX. (3.6m)

V + V

1

+ H = 50’ MAX. (15.2m)

H + H

1

= 18’ MAX. (5.5m)

H + H

1

= 12’ MAX. (3.6m)

Advertising