Heat & Glo Fireplace RCOR-HV-IPI User Manual

Page 25

Advertising
background image

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06

25

Figure 14. Venting with One 90° Elbow

Figure 13. Venting with One 90° Elbow

V

H

H

V

NATURAL GAS - VENTING WITH ONE 90° ELBOW

V (FT.)

H (FT.)

1' MIN. (305mm)

3' MAX. (914mm)

2' MIN. (610mm)

6' MAX. (1.83m)

3' MIN. (914mm)

9' MAX. (2.7m)

4' MIN. (1.22m)

12' MAX. (3.6m)

5’ MIN. (1.5m)

15’ MAX. (4.5m)

6’ MIN. (1.83m)

18’ MAX. (5.5m)

V + H = 50’ MAX. (15.2m)

(11.3m)

PROPANE - VENTING WITH ONE 90° ELBOW

V (FT.)

H (FT.)

1' MIN. (305mm)

2' MAX. (610mm)

2' MIN. (610mm)

4' MAX. (1.22m)

3' MIN. (914mm)

6’ MAX. (1.83m)

4' MIN. (1.22m)

8' MAX. (2.4m)

5’ MIN. (1.5m)

10' MAX. (3.0m)

6’ MIN. (1.83m)

12' MAX. (3.6m)

V + H = 50’ MAX. (15.2m)

NATURAL GAS

VENTING WITH ONE 90° ELBOW

V (FT.)

H (FT.)

90

0

Elbow on top 2.5’ MAX. (64mm)

1' MIN. (305mm)

3' MAX. (914mm)

2' MIN. (610mm)

6' MAX. (1.83m)

3' MIN. (914mm)

9' MAX. (2.7m)

4' MIN. (1.22m)

12' MAX. (3.6m)

5’ MIN. (1.5m)

15’ MAX. (4.5m)

6’ MIN. (1.83m)

18’ MAX. (5.5m)

V + H = 50’ MAX. (15.2m)

PROPANE

VENTING WITH ONE 90° ELBOW

V (FT.)

H (FT.)

90

0

Elbow on top 2’ MAX. (610mm)

1' MIN. (305mm)

2' MAX. (610mm)

2' MIN. (610mm)

4' MAX. (1.22m)

3' MIN. (914mm)

6’ MAX. (1.83m)

4' MIN. (1.22m)

8' MAX. (2.4m)

5’ MIN. (1.5m)

10' MAX. (3.0m)

6’ MIN. (1.83m)

12' MAX. (3.6m)

V + H = 50’ MAX. (15.2m)