Passive infrared/ultrasonic, Occupancy sensors, Ap1277i1 ap1277i1n au1277i1 au1277i1n – Hubbell EDTV CLT2054 User Manual

Page 10: H-moss, Motion switching system, Passive infrared / ultrasonic occupancy sensors, Installation and operating instructions

Advertising
background image

®

Wiring Device-Kellems
Hubbell Incorporated (Delaware)
185 Plains Road
Milford, CT 06461-2420
(203) 882-4800

H-MOSS

®

Motion Switching System

Passive Infrared / Ultrasonic Occupancy Sensors

Installation and Operating Instructions

DESCRIPTION

The H-MOSS® sensor is an intelligent self-adapting occupancy
sensor that is designed to replace existing wall switches.

SPECIFICATIONS

• 1000 sq. ft coverage area (Models: AP1277 and AD1277)
• 400 sq. ft. coverage area (Models: AU1277)
• Single or Dual circuit 120/277VAC, 50/60Hz operation
• Electrical Ratings: (Each Output Separately) 120VAC – 800W

Incandescent, 1000W Ballast, 1/6 HP 277VAC – 1800W Ballast,
1/6 HP

• Adjustable Time Delay: 4-30 minutes, self-adapts based on

occupancy

• Light Level Adjustment (Circuit B output on Dual Circuit versions):

10-500+FC

• UL Listed

PRECAUTIONS

CAUTION: RISK OF ELECTRICAL SHOCK. Turn power off at
service panel before beginning installation. Never wire energized
electrical components.
Read and understand all instructions before beginning installation.
NOTICE: For installation by a licensed electrician in accordance with
National and/or local Electrical Codes and the following instructions.
NOTICE: For indoor use only.
CAUTION: USE COPPER CONDUCTOR ONLY.
Confi rm that device ratings are suitable for the application prior to
installation.
NOTICE: Do not install if any damage to product is noticed.

INSTALLATION

1. Turn power off at the service panel.
2. Remove the old switch(es) if applicable.
3. Wire as shown in the Wiring Diagram section. A secure connection

to ground is necessary for the sensor to function properly.

4. Install sensor in wall box using mounting screws provided.
5. Restore power to the sensor and allow it to self adjust (up to 2min.).
6. Remove the sensor’s cover – see Adjustments section.
7. If desired, calibrate the photocell sensor and adjust the sensor’s

confi guration switch settings as described below.

8. Reinstall the sensor’s cover.
9. Install a Style Line® wall plate (not included).

Test Mode – to enter test mode:

1. Make sure lights are on.
2. Press and hold the ON/OFF button until the lights cycle off then

back on. For dual circuit sensors, press and hold the ON/OFF
button for Circuit A. For No-button sensors, press and hold the
Test Button. See Sensor Operation Diagram.

3. Sensor is now in test mode. Vacate room, lights should turn off

after 5 seconds. Step back into room (sensing zone), lights will
turn back on. Repeat as necessary to confi rm sensor is operating
and detecting in the lighting zone as desired. Sensor will fl ash red
or green LED to indicate Passive Infrared or Ultrasonic occupancy
detection as applicable.

4. To exit Test Mode, press any button. Note: Sensor will automatically

exit Test Mode after 1 hour.

Manual Override – Press button(s) to toggle lights ON and OFF.
Lights will remain in the last state determined by the buttons while
occupancy is detected. Sensor will return to automatic mode when
the sensor’s unoccupied timer value is reached. Note: No-button
sensors cannot be manually turned off.

PD2218

Page 1

04/09 PRINTED

IN USA

Wiring Diagram

Range Diagram

120/277VAC

Black

Green
Ground

Red

Load 1

Single Circuit

US Major

motion

US Minor

motion

PIR Major Motion

50 '

26 '

16 '

29 '
56 '

Sensor Operation Diagram

One/No Button Sensor

Two Button Sensor

Photocell

Push-Button

Confi guration

Switches

Cover Release

Catch

Button A

(Test Button)

Air Gap Switch

Photocell

Push-Button

Confi g-

uration

Switches

Cover Release

Catch

Button A

(Test Button)

Air Gap Switch

Button B

15 '

Line circuit 1
120/277 VAC

Black

Green
Ground

Dual Circuit Sensor

(Wired for Dual Circuits)

Blue

Line circuit 2
120/277 VAC

Red

Load 1

Load 2

Violet

Line circuit
120/277 VAC

Dual Circuit Sensor

(Wired for Single Circuit)

Black

Green
Ground

Blue

Red

Load 1

Load 2

Violet

Load 2

Load1

Load 2

Load1