Precautions, Replacing fuses, Precautions -2 replacing fuses -2 – High End Systems Technobeam User Manual

Page 121: Table 6-1. replacement fuses -2

Advertising
background image

6-2

Precautions

Technobeam

®

User Manual

Precautions

This section lists precautions you must follow anytime you are
servicing the fixture.

WARNINGS

Before performing any service or
maintenance, make note of the following:

(1) Hot lamp may be an explosion hazard. Do
not open for 5 minutes after switching off.
Wear eye and hand protection when re-
lamping.

(2) Equipment surfaces may reach
temperatures up to 70° C (158° F). Allow 5
minutes for cooling before handling.

(3) Disconnect power before re-lamping or
servicing.

(4) Replace fuses with the specified type and
rating
only.

(5) Never look directly at the lamp while
lamp is on.

(6) The procedures in this chapter are
intended to assist qualified service
personnel because Technobeam fixtures are
to be serviced by qualified service
personnel
only.

Replacing Fuses

This section explains how to replace any of the three fuses located on
the fixture’s circuit board. Make note of the warnings in the section
titled “Precautions” on page 6-2.

Note

All fuses are 5 mm x 20 mm.

Table 6-1. Replacement Fuses

Fuse

Amps

Volts

Fuse Type

F1

4.0 A

125 V

Fast Blow Only

F2

2.5 A

250 V

Fast Blow Only

F3

6.3A

250 V

Slow Blow Only