Status leds, Table 2-1. status leds -3 – High End Systems Technobeam User Manual

Page 44

Advertising
background image

Technobeam

®

User Manual

Powering On the Fixture

2-3

Status LEDs

Technobeam fixtures have three status LEDs located on the access
door, as shown in Figure 2-2:

Figure 2-2. Location of the three status LEDs on the fixture’s access door.

Table 2-1 describes the three status LEDs:

If the LED states indicate a problem, see the section titled
“Troubleshooting” on page 2-20.

* - The Receive LED will not be ON unless the fixture is connected to a
DMX 512 link with a working controller. If you have already connected

Table 2-1. Status LEDs

LED name

State

Problem

Indication?

Description

Motor

solid red

No

The motors are receiving adequate
voltage.

OFF

Yes

Fuse or power failure. See below.

Transmit

OFF

Not necessarily* No data is being transmitted.

flickering yellow

No

A software crossload is taking place.

solid yellow

Yes

Software or hardware failure.

Receive

OFF

Not necessarily* No data is being received.

flickering green

No

Fixture is receiving data.

Door retaining screw

Access door