Hand Held Products HANDHELD 3800G User Manual

Page 42

Advertising
background image

3 - 10

3800g User’s Guide

Note: Code 93 must be enabled to use this example.

You would set up the sequence editor with the following command line:

SEQBLK62999941FF6A999942FF69999943FF

The breakdown of the command line is shown below:

SEQBLKsequence editor start command
62

code identifier for Code 39

9999 code length that must match for Code 39, 9999 = all lengths
41

start character match for Code 39, 41h = “A”

FF

termination string for first code

6A

code identifier for Code 128

9999 code length that must match for Code 128, 9999 = all lengths
42

start character match for Code 128, 42h = “B”

FF

termination string for second code

69

code identifier for Code 93

9999 code length that must match for Code 93, 9999 = all lengths
43

start character match for Code 93, 43h = “C”

FF

termination string for third code

To program the previous example using specific lengths, you would have to
count any programmed prefixes, suffixes, or formatted characters as part of the
length. If you use the example on page 3-9, but assume a <CR> suffix and
specific code lengths, you would use the following command line:

SEQBLK62001141FF6A001242FF69001143FF

A - Code 39

B - Code 128

C - Code 93

Advertising