3 - 11

The breakdown of the command line is shown below:

SEQBLK sequence editor start command
62

code identifier for Code 39

0011

Code 39 code length (9) plus CR suffix (2) = 11

41

start character match for Code 39, 41h = “A”

FF

termination string for first code

6A

code identifier for Code 128

0012

Code 128 code length (10) plus CR suffix (2) = 12

42

start character match for Code 128, 42h = “B”

FF

termination string for second code

69

code identifier for Code 93

0011

Code 93 code length (9) plus CR suffix (2) = 11

43

start character match for Code 93, 43h = “C”

FF

termination string for third code

Multiple Symbols

When this programming selection is turned

On

, it allows you to read multiple

symbols with a single pull of the imager’s trigger. If you press and hold the
trigger, aiming the imager at a series of symbols, it reads unique symbols once,
beeping (if turned on) for each read. The imager attempts to find and decode
new symbols as long as the trigger is pulled. When this programming selection
is turned

Off

, the imager will only read the symbol closest to the aiming beam.

No Read

With No Read turned

On

, the imager sends an “NR” to the host if you pull and

release the trigger without reading a code (e.g., bad bar code). If No Read is
turned

Off

, the “NR” will not be sent to the host.

On

* Off

On

* Off