HP 3162 User Manual

Page 101

Advertising
background image

Configuration Options

C-3

3162-A2-GB20-40

August 2000

Table C-1.

Network Interface Configuration Options (2 of 2)

ANSI Performance Report Messages: Disable
Enable Disable

Specifies whether ANSI T1.403 compliant performance report messages (PRMs) are
generated.

Enable – Generates and sends ANSI PRMs over the FDL every second.

Disable – Prevents the DSU/CSU from generating ANSI PRMs.

NOTE:

This configuration option is only available if the framing format is set to
ESF.

Network Initiated LLB: Enable
Enable Disable

Allows initiation and termination of the LLB to be controlled by the receipt of
LLB-Actuate and LLB-Release commands from the network (or remote DSU/CSU).

Enable – Causes the DSU/CSU to enter an LLB (if the DSU/CSU can perform an LLB
in its current state) and to cause an LLB-Release command to terminate the LLB.

Disable – Causes the DSU/CSU to ignore LLB-Actuate and LLB-Release commands
(the DSU/CSU is not in compliance with ANSI T1.403 and AT&T TR 62411).

NOTE:

If this configuration option is enabled, the DSU/CSU recognizes the in-band
LLB-Actuate and LLB-Release codes specified by AT&T as well as the
bit-oriented FDL messages specified by ANSI (for ESF only).

Network Initiated PLB: Enable
Enable Disable

Allows initiation and termination of the PLB to be controlled by the receipt of
PLB-Actuate and PLB-Release commands from the network (or remote DSU/CSU).

Enable – Causes the DSU/CSU to enter a PLB (if the DSU/CSU can perform a PLB in
its current state) and to cause a PLB-Release command to terminate the PLB.

Disable – Causes the DSU/CSU to ignore PLB-Actuate and PLB-Release commands
(the DSU/CSU is not in compliance with ANSI T1.403 and AT&T TR 54016).

NOTES: – If this configuration option is enabled, the DSU/CSU recognizes the

in-band PLB-Actuate and PLB-Release codes specified by AT&T as well
as the bit-oriented FDL messages specified by ANSI.

– This configuration option is only available if the network interface

framing is set to ESF.

Circuit Identifier: Text Field
Text Field
Clear

Specifies the transmission vendor’s circuit identifier for the purpose of facilitating
troubleshooting. The network circuit identifier is an ASCII text string that may be up to
255 characters in length.

Text Field – Allows you to edit or display the network circuit identifier.

Clear – Allows you to clear the network circuit identifier. The network circuit identifier is
set to a null string.

Advertising