Data ports, Table 3-4 – HP 3162 User Manual

Page 30

Advertising
background image

Operation

3-4

3162-A2-GB20-40

August 2000

Table 3-4.

Data Port LEDs

Name

Color

Meaning

DTR

Green

Monitors the state of interchange circuit CD (CCITT 108/1, /2) –
Data Terminal Ready received from the synchronous data DTE.

ON :

DTR is being asserted by the synchronous data
DTE.

OFF :

DTR is not being asserted.

TXD

Yellow

Monitors activity on interchange circuit BA (CCITT 103) –
Transmitted Data. This is the data sent from the synchronous
data DTE to the data port on the DSU/CSU.

ON :

Ones are being received from the synchronous
data DTE.

OFF :

Zeros are being received from the synchronous
data DTE.

CYCLING: Both ones and zeros are being received from the

synchronous data DTE.

RXD

Yellow

Monitors activity on interchange circuit BB (CCITT 104) –
Received Data. This is data sent to the synchronous data DTE
from the data port on the DSU/CSU.

ON :

Ones are being sent to the synchronous data
DTE.

OFF :

Zeros are being sent to the synchronous data
DTE.

CYCLING: Both ones and zeros are being sent to the

synchronous data DTE.

CTS

Yellow

Monitors the state of interchange circuit CB (CCITT 106) –
Clear-to-Send sent to the synchronous data DTE.

ON :

CTS is being asserted by the DSU/CSU.

OFF :

CTS is not being asserted.

RTS

Yellow

Monitors the state of interchange circuit CA (CCITT 105) –
Request-to-Send received from the synchronous data DTE.

ON :

RTS is being asserted by the synchronous data
DTE.

OFF :

RTS is not being asserted.

Advertising