HP 3162 User Manual

Page 68

Advertising
background image

Monitoring and Testing

5-4

3162-A2-GB20-40

August 2000

Table 5-2.

Health and Status Messages (2 of 2)

Message

Description

OOF at DTE

An Out Of Frame condition has been detected on the DTE
Drop/Insert (DSX-1) interface. The condition is cleared when a
reframe occurs.

OOF at Network

An Out Of Frame condition (2 out of 4 frame synchronization bits
in error) has been detected on the network interface. The
condition is cleared when a reframe occurs.

OOF at Port n

An Out Of Frame condition has been detected on data port Port n
(where n is the port number). This condition only occurs if the
synchronous data port’s Embedded Data Link (EDL) is enabled.

Primary Clock
Failed

The primary clock has failed. Timing for the DSU/CSU is provided
by the internal clock.

System Operational

This message only appears if there are no valid alarm or status
messages.

Yellow at DTE

A Yellow Alarm signal is being received by the DTE Drop/Insert
(DSX-1) interface.

Yellow at Network

A Yellow Alarm signal is being received by the network interface.

Advertising