3.

Remove the power supply.

To replace the component, reverse the removal procedure.

Hot-plug fans

The server supports redundant hot-plug fans, each with two individual fans rotors, in a 5+1
configuration to provide proper airflow to the server. The airflow strategy contains two thermal
zones with three fan units in the bottom zone (accessed from the server rear), and three fan units
in the upper zone (accessed internally). See

“Fan locations” (page 75)

.

WARNING!

To prevent personal injury from hazardous energy:

Remove watches, rings, or other metal objects.

Use tools with insulated handles.

Do not place tools or metal parts on top of batteries.

Rear accessed hot-plug fans

To replace a rear accessed hot-plug fan:
1.

Identify the failed fan by locating an amber LED on the Systems Insight Display.

Hot-plug fans

39