7 specifications, Environmental specification, Server specifications – HP DL785 User Manual

Page 81: Environmental specification server specifications

Advertising
background image

7 Specifications

In this section

“Environmental specification” (page 81)

“Server specifications” (page 81)

Environmental specification

Value

Specification

Temperature range

10°C to 35°C (50°F to 95°F)

1

Operating

-30°C to 60°C (-22°F to 140°F)

2

Non-operating

28°C (82.4°F)

Maximum wet bulb temperature

Relative humidity (noncondensing)

3

10% to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-condensing.

Operating

5% to 95% relative humidity (Rh), 38.7°C (101.7°F)
maximum wet bulb temperature, non-condensing.

Non-operating

Altitude

3050 m (10,000 ft). This value may be limited by the type
and number of options installed. Maximum allowable
altitude change rate is 457 m/min (1500 ft/min).

Operating

9144 m (30,000 ft). Maximum allowable altitude change
rate is 457 m/min (1500 ft/min).

Non-operating

1

10° to 35°C (50° to 95°F) at sea level with an altitude derating of 1.0°C per every 305 m (1.8°F per every 1000 ft) above
sea level to a maximum of 3050 m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 10°C/hr
(18°F/hr). The upper limit may be limited by the type and number of options installed.
System performance may be reduced if operating with a fan fault or above 30°C (86°F).

2

Maximum rate of change is 20°C/hr (36°F/hr).

3

Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for
storage corresponds to a pressure minimum of 70 KPa.

Server specifications

Value

Specification

Dimension

30.58 cm (12.04 in)

Height

69.6 cm (27.4 in)

Depth

44 cm (17.32 in)

Width

72 kg (160 lbs)

Weight (maximum

1

)

67 kg (147 lbs)

Weight (minium

2

)

High line

3

200 - 240 V ac

Low line

100 - 120 V ac

Input requirement

180 - 264 V ac

90 - 132 V ac

Rated input voltage

Environmental specification

81