Cm6200 install guide – Firstech, LLC. CM6200 User Manual

Page 16

Advertising
background image

Copyright 2009 Firstech, LLC.

Page 16

CM6200 Install Guide

Starter System

www.firstechonline.com | www.compustar.com

Pin 18 Gray/Black – Hood Pin negative (-) input. This input is a safety shut down and alarm trigger. It prevents

the vehicle from remote starting while the hood is open and triggers the alarm if the hood is opened

while the alarm is armed. You can connect this wire to the hood pin supplied with this kit, or to a wire in

the vehicle that shows (-) only while the hood is open.

Pin 19 Violet [POC 9] - Violet [POC 9] - Auxiliary 1 - 250mA negative (-) output. This is an optional output

that will provide a pulsed, latched, or timed negative output when triggered by the remote(s). This can

be used for power sliding doors, window modules or other outputs.

Pin 20 Brown - Siren 12V positive (+) output. Connect this wire to the (+) wire located on the siren. To change

siren output settings, review Option 3-7.

Connector 4 (CN3) , 20 Pin Blade Connector - New Generation

This connector is used only if you are installing a Blade-AL or Blade-TB. The wiring harness for this connector
only comes with the Blade cartridge. Please refer to the Blade install guide for wire descriptions. The new CM6
Series the Blade connector has a locking tab. Non-locking tab blade harnesses will work but you MUST
TAKE CARE TO NOT PLUG THE HARNESS IN UPSIDE DOWN
. Make sure the two notches on the top
of the harness face the top (CM and barcode sticker side) of the brain. When looking at the wire side of the har-
ness the two notches must be at the top of the plug.

Connector 5 (CN4), 6-Pin

Pin 1 Not used

Pin 2 Violet/White - Trunk release 250mA negative (-) output. This is an optional output that will release the

trunk. Use CN1, Pin 2 if the vehicle is equipped with a (+) trunk release. System will unlock doors and

disarm alarm prior to trunk release.

Pin 3 Orange/Black - 2nd Unlock 250mA negative (-) output. This is an optional output that will provide a (-)

pulse for driver’s priority door lock. IMPORTANT: You must isolate the driver’s door and turn on Op

tion 1-3.

Pin 4 Blue - Unlock 250mA negative (-) output. This is an optional output that will provide a (-) pulse for

unlocking doors. System will unlock doors and disarm alarm. IMPORTANT: You must reverse polarity

for (+) trigger door lock systems. For additional lock settings review Option Group 1 (page 31).

Pin 5 Blue/Black - Lock 250mA (-) negative output. This is an optional output that will provide a (-) pulse for

locking doors. System will lock doors and arm alarm. IMPORTANT: You must reverse polarity for (+)

trigger door lock systems. For additional lock settings review Option Group 1 (page 31).

Pin 6 Not used

Advertising